Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Arq. bras. cardiol ; 111(1): 64-72, July 2018. tab, graf
Article in English | LILACS | ID: biblio-950197

ABSTRACT

Abstract Background: Type 2 diabetes Mellitus (T2DM) is associated with cardiac autonomic dysfunction, which is an independent predictor of mortality in chronic diseases. However, whether the coexistence of systemic arterial hypertension (HTN) with DMT2 alters cardiac autonomic modulation remains unknown. Objective: To evaluate the influence of HTN on cardiac autonomic modulation and cardiorespiratory fitness in subjects with DMT2. Methods: 60 patients of both genders were evaluated and allocated to two groups: DMT2 patients (n = 32; 51 ± 7.5 years old) and DMT2 + HTN patients (n = 28; 51 ± 6.9 years old). RR intervals were obtained during rest in supine position. Linear and nonlinear indices of heart rate variability (HRV) were computed using Kubios HRV software. Pulmonary gas exchange was measured breath-by-breath, using a portable telemetric system during maximal incremental exercise testing on a cycle ergometer. Statistical analysis included Shapiro-Wilk test followed by Student's t Test, Pearson correlation and linear regression. Results: We found that patients in the DMT2+HTN group showed lower values of mean RR intervals (801.1 vs 871.5 ms), Shannon entropy (3 vs 3.2) and fractal dimension SD 1 (9.5 vs 14.5), when contrasted with patients in the DMT2 group. Negative correlations were found between some HRV nonlinear indices and exercise capacity indices. Conclusion: HTN negatively affects the cardiac autonomic function in diabetic patients, who are already prone to develop autonomic dysfunction. Strategies are need to improve cardiac autonomic functionality in this population.


Resumo Fundamento: A diabetes mellitus tipo 2 (DM2) está associada com disfunção autonômica cardíaca, que é um preditor independente de mortalidade em doenças crônicas. No entanto, ainda não se sabe se a coexistência de hipertensão arterial sistêmica (HAS) e DM2 altera a modulação cardíaca autonômica. Objetivos: O objetivo deste estudo foi avaliar a influência de HAS sobre a modulação da função autonômica cardíaca e capacidade cardiopulmonar em indivíduos com DM2. Métodos: 60 pacientes de ambos os sexos foram avaliados e alocados em dois grupos; pacientes DM2 (n = 32; 51 ± 7,5 anos) e pacientes DM2 + HAS (n = 28; 51 ± 6,9 anos). Intervalos RR foram obtidos durante repouso e em posição supina. Índices lineares e não lineares da variabilidade da frequência cardíaca (VFC) foram registrados utilizando-se o programa Kubios HRV software. A troca gasosa pulmonar foi medida a cada inspiração, utilizando-se um sistema telemétrico portátil durante o teste incremental máximo de exercício em cicloergômetro. A análise estatística incluiu o teste Shapiro-Wilk seguido do teste t de Student, a correlação de Pearson e a regressão linear. Resultados: Encontramos que pacientes do grupo DM2+HAS apresentaram valores mais baixos de intervalos RR (801,1 vs 871,5 ms), entropia de Shannon (3,0 vs 3,2) e DP1 da dimensão fractal em comparação aos pacientes do grupo DM2. Foram encontradas correlações negativas entre alguns índices não lineares da VFC e índices da capacidade do exercício. Conclusão: A HAS afeta negativamente a função autonômica cardíaca em pacientes diabéticos, os quais já são propensos a desenvolverem disfunção autonômica. Estratégias são necessárias para melhorar a função autonômica cardíaca nessa população.


Subject(s)
Humans , Male , Female , Middle Aged , Autonomic Nervous System/physiopathology , Diabetes Mellitus, Type 2/physiopathology , Diabetic Angiopathies/physiopathology , Cardiorespiratory Fitness/physiology , Heart Rate/physiology , Hypertension/physiopathology , Cross-Sectional Studies , Diabetes Mellitus, Type 2/complications , Diabetic Angiopathies/etiology , Exercise Test , Hypertension/complications
2.
Braz. j. phys. ther. (Impr.) ; 20(4): 289-297, July-Aug. 2016. tab, graf
Article in English | LILACS | ID: lil-792717

ABSTRACT

ABSTRACT Background Recent studies have shown that the magnitude of the metabolic and autonomic responses during progressive resistance exercise (PRE) is associated with the determination of the anaerobic threshold (AT). AT is an important parameter to determine intensity in dynamic exercise. Objectives To investigate the metabolic and cardiac autonomic responses during dynamic resistance exercise in patients with Coronary Artery Disease (CAD). Method Twenty men (age = 63±7 years) with CAD [Left Ventricular Ejection Fraction (LVEF) = 60±10%] underwent a PRE protocol on a leg press until maximal exertion. The protocol began at 10% of One Repetition Maximum Test (1-RM), with subsequent increases of 10% until maximal exhaustion. Heart Rate Variability (HRV) indices from Poincaré plots (SD1, SD2, SD1/SD2) and time domain (rMSSD and RMSM), and blood lactate were determined at rest and during PRE. Results Significant alterations in HRV and blood lactate were observed starting at 30% of 1-RM (p<0.05). Bland-Altman plots revealed a consistent agreement between blood lactate threshold (LT) and rMSSD threshold (rMSSDT) and between LT and SD1 threshold (SD1T). Relative values of 1-RM in all LT, rMSSDT and SD1T did not differ (29%±5 vs 28%±5 vs 29%±5 Kg, respectively). Conclusion HRV during PRE could be a feasible noninvasive method of determining AT in CAD patients to plan intensities during cardiac rehabilitation.


Subject(s)
Humans , Aged , Coronary Artery Disease/physiopathology , Anaerobic Threshold , Exercise/physiology , Lactic Acid/chemistry , Resistance Training/methods , Heart Rate/physiology
3.
Braz. j. phys. ther. (Impr.) ; 20(2): 184-188, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-783873

ABSTRACT

Background: Portable respiratory inductive plethysmography (RIP) systems have been validated for ventilatory assessment during resting conditions and during incremental treadmill exercise. However, in clinical settings and during field-based exercise, intensity is usually constant and submaximal. A demonstration of the ability of RIP to detect respiratory measurements accurately during constant intensity conditions would promote and validate the routine use of portable RIP devices as an alternative to ergospirometry (ES), the current gold standard technique for ventilatory measures. Objective: To investigate the agreement between respiratory variables recorded by a portable RIP device and by ES during rest and constant intensity exercise. Method: Tidal volume (VT), respiratory rate (RR) and minute ventilation (VE) were concurrently acquired by portable RIP and ES in seven healthy male volunteers during standing rest position and constant intensity treadmill exercise. Results: Significant agreement was found between RIP and ES acquisitions during the standing rest position and constant intensity treadmill exercise for RR and during the standing rest position for VE. Conclusion: Our results suggest that portable RIP devices might represent a suitable alternative to ES during rest and during constant submaximal exercise.


Subject(s)
Humans , Plethysmography , Ventilators, Mechanical , Tidal Volume/physiology , Exercise Test/methods , Respiration , Rest , Exercise
4.
Braz. j. phys. ther. (Impr.) ; 18(1): 9-18, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-704628

ABSTRACT

Objective: To investigate the cardiac autonomic responses during upper versus lower limb discontinuous resistance exercise (RE) at different loads in healthy older men. Method: Ten volunteers (65±1.2 years) underwent the one-repetition maximum (1RM) test to determine the maximum load for the bench press and the leg press. Discontinuous RE was initiated at a load of 10%1RM with subsequent increases of 10% until 30%1RM, followed by increases of 5%1RM until exhaustion. Heart rate (HR) and R-R interval were recorded at rest and for 4 minutes at each load applied. Heart rate variability (HRV) was analyzed in 5-min segments at rest and at each load in the most stable 2-min signal. Results: Parasympathetic indices decreased significantly in both exercises from 30%1RM compared to rest (rMSSD: 20±2 to 11±3 and 29±5 to 12±2 ms; SD1: 15±2 to 8±1 and 23±4 to 7±1 ms, for upper and lower limb exercise respectively) and HR increased (69±4 to 90±4 bpm for upper and 66±2 to 89±1 bpm for lower). RMSM increased for upper limb exercise, but decreased for lower limb exercise (28±3 to 45±9 and 34±5 to 14±3 ms, respectively). In the frequency domain, the sympathetic (LF) and sympathovagal balance (LF/HF) indices were higher and the parasympathetic index (HF) was lower for upper limb exercise than for lower limb exercise from 35% of 1RM. Conclusions: Cardiac autonomic change occurred from 30% of 1RM regardless of RE limb. However, there was more pronounced sympathetic increase and vagal decrease for upper limb exercise than for lower limb exercise. These results provide a basis for more effective prescription of RE to promote health in this population. .


Subject(s)
Aged , Aged, 80 and over , Humans , Middle Aged , Autonomic Nervous System/physiology , Exercise Tolerance/physiology , Heart Rate , Heart/physiology , Lower Extremity/physiology , Upper Extremity/physiology
5.
Braz. j. phys. ther. (Impr.) ; 17(6): 547-555, dez. 2013. tab, graf
Article in English | LILACS | ID: lil-696987

ABSTRACT

BACKGROUND: Transcutaneous electrical diaphragmatic stimulation (TEDS) has been used to improve respiratory muscle strength in patients with respiratory muscle weakness. However, this physical therapy resource has not been studied in chronic obstructive pulmonary disease (COPD). OBJECTIVE: To evaluate the respiratory pattern during one session of TEDS in COPD patients. METHOD: Fifteen COPD patients participated in one TEDS session for plethysmographic analysis and assessment of peripheral oxygen saturation (SpO2) and heart rate (HR). After the session, patients were divided into two groups: Responder (R; n=9) and Non-Responder (NR; n=6) to TEDS. Statistic analysis was performed using the Shapiro-Wilk normality test and two-way ANOVA. For the parameters that showed interaction, the Student t test was used (P<0.05). RESULTS: R group consisted mainly of men, with lower SpO2 and higher HR than NR group. When time (before and during) and groups (R and NR) were compared (interaction), there were differences in the parameters minute ventilation (Vent), inspiratory tidal volume (ViVol), expiratory tidal volume (VeVol), and respiratory rate (Br/M). In the intergroup comparison, differences were observed in the parameters Vent, ViVol, and VeVol. A significant effect was also observed for time in change in end-expiratory lung volume level (qDEEL), phase relation during inspiration (PhRIB); phase relation during expiration (PhREB); phase relation of entire breath (PhRTB), and phase angle (PhAng). During TEDS, there was an increase in SpO2 and a reduction in HR in both groups. CONCLUSIONS: The most hypoxemic group with greater HR responded to TEDS and there was interaction between group and time of analysis for the pulmonary volumes. The time factor had an influence on the two groups with an increase in thoracoabdominal asynchrony. .


Subject(s)
Aged , Female , Humans , Male , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/therapy , Respiration , Transcutaneous Electric Nerve Stimulation , Cross-Sectional Studies , Diaphragm , Transcutaneous Electric Nerve Stimulation/methods
6.
Braz. j. phys. ther. (Impr.) ; 17(4): 401-408, 23/ago. 2013.
Article in English | LILACS | ID: lil-686012

ABSTRACT

BACKGROUND: The cardiovascular system is noticeably affected by respiration. However, whether different inspiratory resistive loading intensities can influence autonomic heart rate (HR) modulation remains unclear. OBJECTIVE: The objective was to investigate HR modulation at three different inspiratory resistive loading intensities in healthy elderly men. METHOD: This was a prospective, randomized, double-blind study that evaluated 25 healthy elderly men. Cardiac autonomic modulation was assessed using heart rate variability (HRV) indices. All of the volunteers underwent maximal inspiratory pressure (MIP) measurements according to standardized pulmonary function measurements. Three randomly-applied inspiratory resistive loading (30, 60 and 80% of MIP) intensities were then applied using an inspiratory resistance device (POWERbreathe, Southam, UK), during which the volunteers were asked to inhale for 2 seconds and exhale for 3 seconds and complete 12 breaths per minute. Each effort level was performed for 4 minutes, and HR and the distance between 2 subsequent R waves of electrocardiogram (R-R intervals) were collected at rest and at each intensity for further HRV analysis. RESULTS : The parasympathetic HRV (rMSSD, SD1 and HF) indices demonstrated lower values at 80% (rMSSD: 19±2 ms, SD1: 13±2 ms and HF: 228±61 ms2) than at 30% MIP (rMSSD: 25±3 ms, SD1: 18±2 ms and HF: 447±95 ms2; p<0.05). CONCLUSIONS: Lower inspiratory resistive loading intensities promoted a marked and positive improvement of parasympathetic sinus node modulation. .


Subject(s)
Aged , Humans , Male , Heart Rate/physiology , Inhalation/physiology , Double-Blind Method , Prospective Studies , Respiratory Function Tests
SELECTION OF CITATIONS
SEARCH DETAIL